



R290 DC Inverter Monobloc Heat Pump-Heating, Cooling & Hot Water
This product is a variable frequency single-unit outdoor air source heat pump that uses environmentally friendly natural refrigerant R290. It is designed for residential and small to medium-sized commercial applications, integrating heating, cooling, and hot water functions.
โย Energy efficiency level A+++/A+++ (35/55ยฐC water outlet
โย The maximum water temperature is 75ยฐC, meeting multiple needs
โย The system water circulation is more comfortable, cooling – cool, but not cold; heating – warm, but not dry
โย Multiple explosion-proof, safe and reliable
Lower utility bills with efficiency ratingup to 27.5 SEER2 and 14.8 HSPF2.
With minimal maintenance and low operating costs.
Reduced noise pollution both indoors and out for more peaceful, comfortable spaces.
Heating operating range from -22ยฐ to 75ยฐ F (-30ยฐ to 24ยฐ C) with built-in basepan heater included.
Bring powerful heating and cooling comfort to any space without the need for ductwork.
R290 refrigerant achieves a 75% reduction in global warming potential for a lower climate impact.
| Model | LRHP-8ID/290/HC | LRHP-10ID/290/HC | LRHP-12ID/290/HC | LRHP-14ID/290/HC | LRHP-16ID/290/HC | ||
| Power Supply | V/Ph/Hz | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | 220~240/1/50 | |
| Heatingย ย (AT7/6,WT30/35) | Capacity | kW | 8.00 | 10.00 | 12.00 | 14.00 | 16.00 |
| Rated Power Input | kW | 1.62 | 2.08 | 2.45 | 2.74 | 3.25 | |
| COP | kW/kW | 4.95 | 4.80 | 4.90 | 5.11 | 4.92 | |
| Heating (AT7/6,WT47/55) | Capacity | kW | 8.00 | 10.00 | 12.00 | 14.00 | 16.00 |
| Rated Power Input | kW | 2.42 | 3.03 | 3.43 | 4.24 | 5.00 | |
| COP | kW/kW | 3.30 | 3.30 | 3.30 | 3.30 | 3.20 | |
| Cooling (AT35,WT23/18) | Capacity | kW | 8.00 | 10.00 | 11.40 | 14.00 | 16.00 |
| Rated Power Input | kW | 1.63 | 2.15 | 2.78 | 2.74 | 3.33 | |
| EER | kW/kW | 4.90 | 4.65 | 4.10 | 5.11 | 4.80 | |
| Cooling (AT35,WT12/7) | Capacity | kW | 8.00 | 10.00 | 11.40 | 14.00 | 16.00 |
| Rated Power Input | kW | 2.50 | 3.33 | 4.07 | 4.52 | 5.51 | |
| EER | kW/kW | 3.20 | 3.00 | 2.80 | 3.10 | 2.90 | |
| SCOP | Average Climate | 35โ | 4.90 | 4.90 | 4.90 | 5.20 | 4.90 |
| 55โ | 3.85 | 3.85 | 3.85 | 3.90 | 3.90 | ||
| Season space heating energy efficiency class | Average Climate | 35โ | A+++ | A+++ | A+++ | A+++ | A+++ |
| 55โ | A+++ | A+++ | A+++ | A+++ | A+++ | ||
| SEER | Fan Coil Application | 7โ | 4.50 | 4.50 | 4.50 | 5.10 | 5.10 |
| Cooling Floor Application | 18โ | 6.30 | 6.50 | 6.20 | 7.00 | 7.00 | |
| R290 | kg | 1.30 | 1.30 | 1.35 | 1.95 | 1.95 | |
| Heater power input | kW | 3.00 | 3.00 | 3.00 | 6.00 | 6.00 | |
| Sound Power Level (EN12102-1) | dB | 66.00 | 66.00 | 68.00 | 68.00 | 68.00 | |
| Water Pump | Rated Water Flow | m3ย /h | 1.38 | 1.72 | 2.06 | 2.41 | 2.75 |
| Total Water Head | m | 12.50 | 12.30 | 12.00 | 11.50 | 11.10 | |
| Available Water Head | m | 9.00 | 8.80 | 8.50 | 8.00 | 7.60 | |
| Maximun working pressure of refrigerant | MPa | 0.85/3.2 | 0.85/3.3 | 0.85/3.4 | 0.85/3.5 | 0.85/3.6 | |
| Water Side Safety Valve | MPa | 0.60 | 1.60 | 2.60 | 3.60 | 4.60 | |
| Maximum power and maximum current | kW/A | 7.20/32.73 | 8.20/37.27 | 8.70/39.55 | 15.00/68.00 | 16.00/73.00 | |
| Net/gross weight | kg | 147/170 | 147/170 | 154/177 | 183/210 | 183/210 | |
| Water proof grade | / | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
| Water Side Connection | Inch | 1′ | 1′ | 1′ | 1′ | 1′ | |
| Net Dimension (WxDxH) | mm | 1312x530x992 | 1312x530x992 | 1312x530x992 | 1312x530x1370 | 1312x530x1370 | |
| Package Dimension (WxDxH) | mm | 1362x567x1167 | 1362x567x1167 | 1362x567x1167 | 1362x567x1560 | 1362x567x1560 | |
| Ambient Temperature Range | Cooling | โ | 10๏ฝ48 | 10๏ฝ48 | 10๏ฝ48 | 10๏ฝ48 | 10๏ฝ48 |
| Heating | โ | -30๏ฝ35 | -30๏ฝ35 | -30๏ฝ35 | -30๏ฝ35 | -30๏ฝ35 | |
| Domestic Hot Water | โ | -30๏ฝ43 | -30๏ฝ43 | -30๏ฝ43 | -30๏ฝ43 | -30๏ฝ43 | |
| Leaving Water Temperature Range | Cooling | โ | 5๏ฝ25 | 5๏ฝ25 | 5๏ฝ25 | 5๏ฝ25 | 5๏ฝ25 |
| Heating | โ | 24๏ฝ75 | 24๏ฝ75 | 24๏ฝ75 | 24๏ฝ75 | 24๏ฝ75 | |
| Domestic Hot Water | โ | 30๏ฝ60 (Depend on water tank which suppied by user) | |||||
Extremely cold heating capacity
Stable operation at -30ยฐC, with an outlet water temperature up to 75ยฐC.
Dual high efciency in cooling and heating
Inverter technology achieves an EER of 4.5+ for cooling and a COP of 4.8+ for heating.
Quiet operation
Full DC inverter + acoustic optimization, minimum noise level 48dB(A).
Simple installation
No professional refrigerant piping welding is needed; standard plumbers can complete the installation,
shortening the construction period by 50%.
FAQs
A: ย The R290 DC Inverter Monobloc Heat Pump is designed forย residential and small to medium-sized commercial applications. It is an all-in-one outdoor air source heat pump that integratesย heating, cooling, and domestic hot waterย into a single system. Ideal use cases include:
-
Single-family homes, villas, and apartments
-
Small to medium commercial buildings, offices, hotels, and residential complexes
-
Retrofits and new builds where space is limited and installation simplicity is prioritized
A: monobloc heat pumpย houses all key componentsโcompressor, heat exchanger, and refrigerant circuitโin aย single outdoor unit. Only water pipes connect the outdoor unit to the indoor heating system;ย no refrigerant pipes run through the building. Aย split heat pump, by contrast, has separate indoor and outdoor units connected by refrigerant piping.
Key advantages of monobloc:
-
Easier installationย โ no F-gas certified installers required; refrigerant stays sealed outdoors
-
Saferย โ no risk of refrigerant leaks inside the building
-
Lower maintenanceย โ single unit service vs. separate indoor/outdoor maintenance
-
More compactย โ ideal for limited indoor space
A: The R290 DC Inverter Monobloc Heat Pump deliversย exceptional energy efficiency, achieving:
-
Seasonal efficiency rating of A+++ย at both 35ยฐC and 55ยฐC water outlet temperatures
-
COP (Coefficient of Performance) up to 5.11ย under optimal conditions (e.g., 8kW model at 5.11 COP)
-
SCOP (Seasonal COP) up to 5.23ย for low-temperature applications
-
Up toย 27.5 SEER2ย cooling efficiency andย 14.8 HSPF2ย heating efficiency
R290โs thermodynamic properties enableย higher efficiency with lower refrigerant chargeย compared to synthetic refrigerants like R32 or R454B. Compared to R410A systems, R290 units can deliverย up to 7% higher SCOP, translating to significant lifetime energy savings.
A: Yes.ย The R290 DC Inverter Monobloc Heat Pump is engineered forย cold climate performance:
-
Heating operation range down to -30ยฐCย ambient temperature
-
Many models operate reliably down toย -25ยฐC to -28ยฐC
-
Deliversย high water temperatures up to 75ยฐC, even in low ambient conditions
-
Some models achieveย 75ยฐC water output down to -15ยฐCย ambient
This makes the unit suitable forย traditional radiator heating systemsย andย boiler replacement projectsย without modifying existing emitters. Wide operating range ensuresย consistent, reliable performanceย in demanding climates across Scandinavia, Canada, and other cold regions.
A: R290 (propane) is a natural refrigerant with multiple advantages over synthetic alternatives:
| Feature | R290 Advantage |
|---|---|
| GWP | Ultra-low Global Warming Potential ofย only 3 |
| Carbon reduction | Reduces carbon emissions byย up to 79%ย vs. traditional boilers |
| Compliance | Aligns withย EU F-gas regulationsย banning HFC refrigerants with GWP โฅ150 from 2027 |
| Efficiency | High thermodynamic efficiency withย lower refrigerant charge volumes |
| Sustainability | Achievesย 75% reductionย in global warming potential vs. conventional refrigerants |
R290 is theย future-proof refrigerant choiceย for buyers prioritizing sustainability, regulatory compliance, and low operating costs.
A: While R290 isย flammableย (A3 safety classification), modern R290 monobloc heat pumps are designed withย multiple safety protections:
Installation requirements:
-
R290 monobloc units areย self-contained outdoor systemsย โ refrigerant is sealed in the outdoor unit
-
No refrigerant piping inside the building,ย eliminating indoor leak risks
-
Installation requires onlyย water pipe connectionsย and power supply
-
No F-gas certified installer required for the monobloc design
Safety clearancesย (varies by manufacturer, typical guidelines):
-
Minimumย 80 cmย distance from walls
-
No building openings (windows, doors, ventilation) or ignition sources withinย 1 meterย of the outdoor unit
Manufacturer support:ย Leading brands offerย dedicated R290 trainingย covering specific handling requirements for the flammable refrigerant. The EU-funded SKILLSAFE project also provides guidelines for safe R290 heat pump handling.
More Information
Related News
High-efficiency installation cuts energy costs by over 70% compared to electric boilers and delivers annual COโ reductions of 77 tons […]
1. From “Lighthouse Factory” to “Lights-Out Factory”: A Dual-Wheel Drive for Intelligent Manufacturing Upgrades 1.1 Heat Pump Smart Factory: Ushering […]
Get A Quote
Weโre here to help! Please ๏ฌll out our inquiry form, and our team will respond promptly.


